11. To select the Secondary output (Cool), the value between 0 and 11
must be assigned as per the below table:
Secondary output
(Cool)
Serial value
none 0
Relay / Triac 2
Logic 6
0 .. 5 V 7
1 .. 5 V 8
0 .. 10 V 9
0 .. 20 mA 10
4 .. 20 mA 11
12. To select the 1
st
retransmitted output selection, the value between 0
and 2 must be assigned as per the below table
1
st
retransmitted output
selection
Serial value
none 0
Provess variable 1
Setpoint 2
13. To select the 1
st
retransmission output, the value between 7 and 11
must be assigned as per the below table:
1
st
retransmission
output
Serial value
0 .. 5 V 7
1 .. 5 V 8
0 .. 10 V 9
0 .. 20 mA 10
4 .. 20 mA 11
14. To select the remote Setpoint input, the value between 18 and 22
must be assigned as per the below table:
Remote Setpoint input Serial value
0 .. 5 V 18
1 .. 5 V 19
0 .. 10 V 20
0 .. 20 mA 21
4 .. 20 mA 22
15. To select the Setpoint type, the value between 0 and 5 must be
assigned as per the below table:
Setpoint type Serial value
Local only 0
Remote only 1
Local/Remote only 2
Local - Trim 3
Remote - Trim 4
Setpoint Programmer
(option)
5