Specifications

GENERAL INTRODUCTION
SECTION
1
1.1
General Description and Cautions
Athena Controls, Inc. is proud of the Series 6075 which you will now use It
has been manufactured to our
exacting
production standards, and packed
for
maximum
protection in shipment You will get years of reliable
service
from the unit if the information in the manual is followed regarding location,
adjustments, and general operation.
CAUTlON
High Voltage and High Temperature can cause injury and are a
Fire Hazard. Please read all instructions, have only skilled profes-
sionals
wire the unit, and use an approved temperature
and/or
pressure safety control. Even the best components can be
damaged or may not failsafe.
Warning Notes:
1. "B"
Output for resistance load only.
2.
An open thermocouple will disable the INDEX function.
3.
Note also that in units utilizing only heating output the cooling
gain
should be set by user to the equivalent heating gain. The inverse IS
also true.
4.
A unique algorithm in the Model 6075 prevents continual buildup of
oscillation due to grossly misadjusted rate/reset
(-rt-)
or gain. When
this occurs the unit
will
control at some point higher or lower than set
point
outside the proportional band. If this occurs -rt- was probably set
too low and/or gain set too high.
5.
-rt-
sets Rate
(Derivative)
and Reset (Integral) action. The number dis-
played is the Rate time in seconds. This is tracked by the Reset time in
seconds (1:6 ratio).