User Manual

XBee® Wi-Fi RF Modules
© 2012 Digi International, Inc. 81
AT
Command
Name and Description
Parameter
Range
Default
D0 DIO0/AD0 Configuration. Select/Read function for DIO0/AD0.
0 = Disabled
2 = Analog input
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0
D1 DIO1/AD1 Configuration. Select/Read function for DIO1/AD1
0 - Disabled
1 = SPI Attention
2 = Analog input
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0
D2 DIO2/AD2 Configuration. Select/Read function for DIO2/AD2
0 = Disabled
1 = SPI Clock
2 = Analog input
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0
D3 DIO3/AD3 Configuration. Select/Read function for DIO3/AD3
0 = Disabled
1 = SPI Slave Select
2 = Analog input
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0
D4 DIO4 Configuration. Select/Read function for DIO4
0 = Disabled
1 = SPI_MOSI
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0
D5 DIO5 Configuration. Select/Read function for DIO5
0 = Disabled
1 = Associated LED
3 = Digital input
4 = Digital output,
default low
5 = Digital output,
default high
1