User Manual
XBee® Wi-Fi RF Modules
© 2012 Digi International, Inc. 62
Transmitting and Receiving RF Data
The following image shows the API exchanges that take place at the UART or SPI when
sending RF data to another device. The transmit status frame is always sent at the end
of a data transmission unless the frame ID is set to 0 in the transmit request. If the
packet cannot be delivered to the destination, the transmit status frame will indicate
the cause of failure. The received data frame (0x80 or 0xB0) is set by the AP command.
Remote AT commands
The following image shows the API frame exchanges that take place at the UART or SPI
when sending a remote AT command. A remote command response frame is not sent
out the UART or SPI if the remote device does not receive the remote command.