User manual

Table Of Contents
CN6000 User Manual
26
Customization
This configuration dialog allows the Administrator to set Timeout, Login
failure, and Working mode parameters.
An explanation of the Customization parameters is given in the table below:
Time out Control If the CN6000 doesn't receive any input from a computer that is
accessing it with the Windows or Java client for the amount of
time specified here, it ends the connection.
Login failure Login failures allowed, sets the number of consecutive failed
login attempts that are permitted from a remote computer. Login
failure timeout, sets the amount of time a remote computer must
wait before attempting to login again after it has exceeded the
number of allowed failures.
Working Mode If Stealth Mode is enabled, the CN6000 cannot be pinged. If
Echo Mode is disabled, the CN6000 will not show up in the list
of local CN6000 units. See the CN6000 AP version manual
(provided on the CD that came with this package) for details.
Multiuser Operation Enabling Multiuser operation permits more than one user to log
into the CN6000 at the same time.
Reset on exit Placing a check here causes the CN6000 to reset itself and
implement all the new changes when you log out. A wait of
approximately 30 to 60 seconds is necessary before logging in
following the reset.
cn6k_2007-02.book Page 26 Wednesday, February 28, 2007 9:26 AM