8.4. Additional external wiring requirements
For all external wiring, shielded cables should be used except for loudspeaker wires.
Especially for longer cables, care should be taken that this shielding is firmly connected to
earth.
Logic inputs,connected externally with wires longer than 3m, should be provided with ferrite
clamps.
(f.i. Wurth STER-TEC & STAR-FIX LFS or equivalent to cover the 300k-1GHz range)
For all other long cables this is also recommended.
Internal cabling :
High current wires should be separated from audio and data cabling. Use of a separate cable
duct is recommended.
For long loudspeaker wires, it is advised to add an external surge protection circuit.(figure x)
Figure X