User guide
Note (1): All input voltage specifications are for Line
-
to
-
Line three phase, delta or wye. Model 3000Ls (208 V input) can be
operated on 230 V L
-
N single
-
phase if needed.
Options
Option Matrix:
Note that some options are mutually exclusive as indicated in the table below. An
o
means the options can be combined. An
x
means they cannot.
13500Ls
13.5 kVA
1/3
208
-
230V
±
10 %
13500Ls
-
400
13.5 kVA
1/3
400V
±
10%
18000Ls
18 kVA
1/3
208
-
230V
±
10 %
C prefix Cabinet System. Installed and pre
-
wired in 19
cabinet.
Input Options
-
400
400 Volt Line
-
to
-
Line AC input.
[Not available on 6000Ls model or 12000Ls and 18000Ls Systems]
Output Options
-
AX
1
Auxiliary outputs, 26 VAC, 5 VAC. Limits upper frequency to 800 Hz.
-
HV
1
135/270 V output range.
-
EHV
1
200/400 V output range.
-
HF
1
Extends upper frequency limit. See HF table.
HF Table
Models
Max. Freq.
3000Ls, 4500Ls, 6000Ls
5000 Hz
9000Ls/2, 12000Ls/2, 13500Ls/2, 18000Ls/2
2000 Hz
-
LF
1
Limits output frequency to 500 Hz.
Note 1: See option matrix
Keypad Options
-
KPD
Upgraded keypad control panel.
Controller Options
-
160
RTCA/DO
-
160D, Change 2, EuroCAE
-
14D and Airbus test firmware [Section 16, AC only]
-
704
Mil-
Std 704 Rev D and E test firmware. [AC only]
-
ABD
Airbus Directive 0100.1.8 tests. [AC only]. Requires
-
ADV and use of Windows PC and included LxGui software.
-
ADV
Advanced feature set. Adds arbitrary waveform generation and harmonic analysis of voltage and current.
-
GPIB
GPIB interface and APE programming language
-
LAN
Ethernet Interface
-MB
Multi
-
box. Adds controller to auxiliary chassis of multi
-
chassis systems.
-
MODE
Adds phase mode selections for
-
3 models.
-
L22
Locking Knobs
-
LKM
1
Clock and Lock Master
-
LKS
1,2
Clock and Lock Auxiliary
-
LNS
2
Line Sync.
-
EXS
2
External Sync.
Note 1: See option matrix
Note2 :
-
LKS,
-
LNS and
-
EXS are mutually exclusive and with Ext Trig function.
Cabinet Options
-
RMS
Rack
-
mount slides. Recommended for rack
-
mount applications.
C prefix
Cabinet System. Installed and pre
-
wired in 19
cabinet.
HF
LF
HV
EHV
LKM
LKS
EXS
AX
HF
- x o o x x x x
LF
x - o o o o o o