User guide
-
ADV Option
Waveforms
Pre defined: Sine, Square, Clipped
User defined, 1024 addressable data points.
Storage: 50 user waveforms, non
-
volatile memory.
Data Acquisition
Parameters: Voltage, Current time domain, per phase.
Resolution: 4096 data points, 10.4 usec (1 phase) or 31.25 usec (3 phase) sampling interval.
Measurements
-
Harmonics
* Accuracy specifications are in % of reading for single unit in 3 phase mode.
-
HV Option
Voltage Ranges
Max RMS Current @ full power
Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls and max
voltage for 6000Ls.
Max RMS Current @ FS Voltage
Frequency Range:
With
-
HF option:
3000Ls, 4500Ls, 6000Ls:
45 Hz
-
5000 Hz
9000Ls, 12500Ls, 13500Ls, 18000Ls:
45 Hz
-
2000 Hz
-
EHV Option
All specifications same as standard Ls models except where noted.
Voltage Ranges
Max RMS Current @ full power
Parameter
Range
Accuracy* (
±)
Resolution
Frequency
Fundamental
45
-
250 Hz
0.09
-
12.5 kHz
0.1% + 1 digit
0.5% + 1 digit
0.01 Hz
0.1 Hz
Voltage
Fundamental
Harmonics 2
-
50
0.05% + 250mV
0.1%+0.1%/KHz+250mV
10 mV
10 mV
Current
Fundamental
Harmonics 2
-
50
50 mA
0.1% + 50 mA +0.1% /1 kHz
10 mA
10 mA
Low :
0-
156 Volt
High :
0-
312 Volt
V Range
V high V low
Mode:
3 Phs
6.4 A
12.8 A
Mode:
1 Phs
19.2 A 38.4 A
V Range
V high V low
3000Ls
3 Phs
1 Phs
3.2 A
9.6 A
6.4 A
19.2 A
4500Ls
3 Phs
1 Phs
4.8 A
14.4 A
9.6 A
28.8 A
6000Ls
3 Phs
1 Phs
6.4 A
19.2 A
12.8 A
38.4 A
Low :
0-
200 Volt
High :
0-
400 Volt
V Range
V high V low
Mode:
3 Phs
5.0 A
10.0 A