Manual
Operating Modes
AC, DC or AC + DC
AC Mode Output
Frequency
16.00 Hz - 500.0 Hz
Power
Maximum AC power per phase
at full scale voltage:
Model: Power
3001iX
3000 VA
5001iX
5000 VA
10001iX
10000 VA
15001iX
15000 VA
15003iX
(with mode-iX)
5000 VA/ø 3ø
15000 VA/ø 1ø
Power Factor
0 to unity at full output VA
AC Voltage
Ranges User selectable
voltage range pairs:
Range: Low High
Max Vrms 135 V 270 V
Max Vrms 150 V 300 V
Load Regulation
± 0.5% DC to 100 Hz
± 0.6 % 100 Hz to 500 Hz in high
voltage range
± 2.2 % 100 Hz to 500 Hz in low
voltage range
Line Regulation < ± 0.1% for 10
% line change
Output Noise < 250 mV
rms
typ.
(20 kHz to 1 MHz) < 500 mV
rms
max.
Harmonic Distortion (linear load)
Less than 1% from 16 - 66 Hz
Less than 2% at 400 Hz
DC Offset < 20 mV
External Modulation
depth: 0 - 10 %
Isolation Voltage
300 V
rms
output to chassis
AC Current
Peak Repetitive AC Current
Model High
range
Low
range
3001iX
96.0 110.0
5001iX
96.0 110.0
10001iX
192.0 220.0
15001iX
288.0 330.0
15003iX 1ø
288.0 330.0
3ø 96.0 110.0
AC Current
Steady State AC Current
Model 270 V
range
135 V
range
3001iX
11.1 22.2
5001iX
18.5 37.0
10001iX
37.0 74.0
15001iX
55.5 111.0
15003iX 1ø
55.5 111.0
3ø 18.5 37.0
Model 300 V
range
150 V
range
3001iX
10.0 20.0
5001iX
16.7 33.3
10001iX
33.3 66.7
15001iX
50.0 100.0
15003iX 1ø
50.0 100.0
3ø 16.7 33.3
Programming Accuracy
Voltage (rms): ± 0.5 % of range,
16 to 400 Hz
Frequency: ± 0.01 % of
programmed value.
Current Limit: - 0 % to + 7 % of
programmed value + 0.5 A.
Phase: < 1.5° with
balanced load @ 50/60 Hz.
Programming Resolution
Voltage (rms): 100 mV
Frequency:
0.01 Hz from 16 Hz to 81.91 Hz
0.1 Hz from 82.0 Hz to 500.0 Hz
Current Limit:
0.1 A for 5001iX and 15003iX.
1.0 A for 10001iX and 15001iX.
Phase: 0.1°
iX Series - Specifications
1
Standard Measurements (5001iX)
Parameter Range Accuracy
*
(±) Resolution
*
AC Measurements
Frequency 16.00 - 500.0 Hz 0.01% + 0.01 Hz 0.01 Hz
< 100 Hz 100 - 500
Hz
RMS Voltage 0 -330 V 50 mV 100 mV 10 mV
RMS Current 0 - 40 A 50 mA 100 mA 1 mA
Peak Current 0 - 119 A 50 mA 100 mA 1 mA
Crest Factor 0.000 - 6.000 0.05 0.05 0.01
Real Power 0 - 6 kW 5 W 5 W 1 W
Apparent
Power
0 - 6 kVA 10 VA 20 VA 1 VA
Power Factor 0.00 - 1.00 0.01 0.01 0.01
DC Measurements
DC Voltage 0 - 420 V 500 mV 10 mV
DC Current 0 - 120 A 500 mA 1 mA
Power 0 - 6 kW 50 W 1 W
* Measurement system bandwidth = DC to 19.5 kHz. Accuracy specifications are valid above 100
counts. Current and Power Accuracy specifications are times two for 10001iX and times three for
15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for current and
power increases by factor of three.
Harmonics Measurements
Parameter Range Accuracy
*
(±) Resolution
Frequency
Fundamental 16.00-500.0 Hz 0.01% + 0.01 Hz 0.01 Hz
Harmonics 32.00 Hz - 19.5 kHz 0.01 Hz
Phase 0.0 - 360.0° 2° typ. 0.5°
Voltage Fundamental 250 mV 10 mV
Harmonics 2 - 50 0.1% + 250 mV+0.1% /1 kHz 10 mV
Current Fundamental 50 mA 10 mA
Harmonics 2 - 50 0.1% + 50 mA +0.1% /1 kHz 10 mA
* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for
three phase mode. Harmonics frequency range in three phase mode is 32 Hz - 6.67 kHz. Resolution
decreases by factor of 10 for 10001iX and 15001iX.