Instruction Manual
TECHNICAL SPECIFICATIONS
Thefollowingsubsectionsprovideenvironmental,electrical,andphysicalcharacteristicsfortheSPSMEDIUMPOWERSeriespowersupplies.
ENVIRONMENTAL CHARACTERISTICS
PARAMETER SPECIFICATION
TEMPERATURECOEFFICIENT 0.02%/°Cofmaximumoutputvoltageratingforvoltagesetpoint.0.03%/°Cof
maximumoutputcurrentratingforcurrentsetpoint.
AMBIENTTEMPERATURES
Operating 0to50°C
Storage -25°to65°C
COOLING Internalfans;ventsonsidesandrear.(Unitsmaybestackedwithoutclearanceaboveorbelow).
HUMIDITY 95%maximum,non-condensing,0to50°C;45°Cmaximumwet-bulbtemperature
ALTITUDE Operatingfullpoweravailableupto5,000feet(1,524m),derate10%offullpowerforevery1,000feet
higher;non-operatingto40,000feet(12,192m)
Regulatory
CertiedtoUL/CSA61010andIEC/EN61010-1byaNRTL,CECompliant,Semi-F47Compliant.
LVDCategories:InstallationCategoryII:PollutionDegree2;ClassIIEquipment:forIndoorUseOnly.
EMCDirective,EN61326:1998
ELECTRICAL CHARACTERISTICS
PARAMETER SPECIFICATION
INPUTPOWER
Voltage(Standard)
208/220VAC±10%(allowedrange187-242VAC)
Voltage(Options)
380/400VAC±10%(allowedrange342-440VAC)440/480VAC±10%(allowedrange396-528VAC)
Frequency
47to63Hz,400Hz3Umodels,47to63Hz6Umodels
Phases
3-phase,3-wireplusground.Notphaserotationsensitive.Neutralnotused.
PowerFactor
>0.9typicalfor208/220VACinput(10V-800V)
>0.78typicalfor380/400VACinput(40V-800V)
>0.9typicalfor380/480VACinput(10V-30V)
>0.7typicalfor440/480VACinput(40V-800V)
>0.9typicalfor440/480VACinput(10V-30V)
Efciency
87%typicalatfullload,nominalline
FRONTPANELMETERACCURACY
Voltage A-Panel:±0.5%offull-scale+1DigitK-Panel:±0.15%offull-scale
Current A-Panel:±0.5%offull-scale+1DigitK-Panel:±0.4%offull-scale
LOADREGULATION (Speciedatnoloadtofullload,nominalACinput,withsensewiresused)
Voltage ±0.02%(40-800Voutput)±0.5%(10-30Voutput)ofmaximumoutputvoltage
Current ±0.1%ofmaximumoutputcurrent
LINEREGULATION (Specied±10%ofnominalACinput,constantload,withsenselinesused)
Voltage ±0.01%ofmaximumoutputvoltage(40-800Voutput),±0.05%(10-30Voutput)
Current ±0.05%ofmaximumoutputcurrent
TRANSIENTRESPONSE A50%steploadwillrecovertowithin0.75%oforiginalvaluewithin1ms.
DOWNPROGRAMMING Withnoloadtheoutputwillprogramfrom100to10%inlessthan1.5seconds
STABILITY ±0.05%ofsetpointafter30minutewarm-upandover8hourline,loadandtemperature.