Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA E8362C PNA E8363C PNA E8364C PNA E8361C 10 MHz to 20 GHz 10 MHz to 40 GHz 10 MHz to 50 GHz 10 MHz to 67 GHz This guide describes standard configurations, for the PNA (E836xC) Series microwave network analyzers. This guide should be used with the Agilent PNA family data sheets for a complete description of these analyzers.
Agilent offers the following options for all PNA family network analyzers Certification options □ Commercial calibration certification with test data (Option UK6) Complete set of measurements which tests unit to manufacturer’s published specifications. Includes calibration label, calibration certificate, and data report. Conforms to ISO 9001. □ ISO 17025 compliant calibration (Option 1A7) Complete set of measurements which tests unit to manufacturer’s published specifications.
PNA Series Network Analyzer E8362C 10 MHz to 20 GHz E8363C 10 MHz to 40 GHz E8364C 10 MHz to 50 GHz E8361C 10 MHz to 67 GHz Option configurations To add options to a product, order the corresponding item number.
PNA Series Network Analyzer The microwave PNA Series instruments are integrated vector network analyzers equipped with a built-in S-parameter test set, synthesized source, a hard disk drive, USB interfaces, and an 8.4” LCD color touch screen display. The E8362C has 3.5 mm male 50-ohm test ports. The E8363C/64C have 2.4 mm male 50-ohm test ports. The E8361C has 1.85 mm male 50-ohm test ports. Included with each instrument is a mouse, keyboard (U.S.) and a 1-year return-to-Agilent service warranty.
PNA Series Network Analyzer □ 4-port measurement application (Option 550) Adds multiport analyzer mode to any PNA network analyzer with Option 014 configurable test set, which enables full 4-port error correction and measurement capabilities using an external test set. Only standard measurement class is available in the multiport analyzer mode.
PNA Series Network Analyzer Simplified test set block diagrams Standard power range Source Switch/splitter R1 Reference receiver Reference receiver A B R2 Measurement receivers Port 1 Port 2 Extended power range and bias-tees (Option UNL) Source Switch R1 Reference receiver Reference receiver Source attenuator1 R2 Source attenuator1 Bias-tee Bias-tee A Measurement receivers Port 1 1. Source attenuator for E8362/3/4C is 60 dB in 10 dB steps.
PNA Series Network Analyzer Simplified test set block diagrams – continued Configurable test set (Option 014) Source Switch R1 Reference receiver Reference receiver A B R2 Measurement receivers Port 1 Port 2 Configurable test set with extended power range and bias-tees (Option UNL and 014) Source Switch R1 Reference receiver Reference receiver Source attenuator1 Bias-tee R2 Source attenuator1 B A Bias-tee Measurement receivers Port 1 Port 2 1.
PNA Series Network Analyzer Simplified test set block diagrams – continued Fully optioned, active device or mixer/converter test configuration (Options 014, UNL, 016, 080, 081) Source Switch/splitter/leveler R1 Reference receiver Reference receiver Source attenuator1 Option 081 R2 Source attenuator1 Measurement receivers 10 dB steps Bias-tee A 10 dB steps Bias-tee B Receiver attenuator2 Source out Rcvr R1 in SRC out Cplr thru Cplr arm 1.
PNA Series Network Analyzer Simplified test set block diagrams – continued High-power configuration (Model E836xCH85) Source Switch/splitter/leveler +30 dBm Reference receiver Reference receiver +15 R1 dBm Source attenuator1 Source attenuator1 +30 dBm Option 081 10 dB steps A +30 dBm +40 dBm Rcvr R1 in SRC out +30 dBm Measurement receivers +15 dBm Source out +15 R2 dBm Cplr thru Cplr arm +15 dBm B Receiver attenuator2 Rcvr A in 10 dB steps +30 dBm Rcvr B in +40 dBm Cplr arm Cplr
PNA Series Network Analyzer Simplified test set block diagrams – continued Fully optioned, pulse-RF, antenna, or mm-wave configuration (Options 014, UNL, 016, 080, 081, H11) Aux RF out (2 to 20 GHz) Rear Aux LO out (2 to 20 GHz) YIG source Option 080 Option H11 Multipliers (1, 2) Phase-locked loop 8.
PNA Series Network Analyzer Upgrade kits Upgrade kits for the PNA Series E8361C, E8362C, E8363C, E8364C Upgrade kits are available to add options after initial purchase. To order an upgrade kit for the PNA series, order the analyzer’s model number followed by a “U”, then indicate the option to be added (for example, E8362CU-010). The current configuration and serial number of the instrument to be retrofitted are required as part of the order. □ Time-domain (Option 010) User installable.
www.agilent.com www.agilent.com/find/pna For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium.