MODEL 1002 1003 1005 1010 1020 1030 1040
INPUT SPECIFICATIONS
Phase 1Ø/2W + ground 3Ø/3W + ground
Voltage 230V±15% 220, 240, 380, 415, 480V±10%
Frequency 47-63Hz
OUTPUT SPECIFICATIONS
Power rating 2kVA 3kVA 5kVA 10kVA 20kVA 30kVA 40kVA
Max Arms @ 0-150 V 16.8 A 25.2 A 42 A 84 A 168 A 252 A 336 A
Max Arms @ 0-300 V 8.4 A 12.6 A 21 A 42 A 84 A 126 A 168 A
Phase 1Ø/3W (L, N, G)
Voltage
Low Range 0-150V
HIgh Range 0-300V
Resolution 0.1V
Accuracy ±(1%+0.2V)
Frequency
Range 45-500Hz
Resolution 0.1Hz at 45-99.9Hz, 1Hz at 100-500Hz
Accuracy ±0.2%
Harmonic Distortion 1%(Resistance Load)
Crest Factor 3 to 1
Load Regulation ±0.5%
Protection Over Current, Short Circuit, Over Temperature
Efficiency 85% (at full load)
Operating Temperature 32°-104°F, (0°-40°C), 80% Relative Humidity
Altitude below 6500 feet
DISPLAYS AND CONTROLS
4 Digital LED meters Frequency, Voltage, Current, Power or Power Factor (simultaneously)
PLC Remote Interface M1, M2, M3, and Output On/Off
Memory 3 Programmable Memory Locations for Voltage, Frequency and Current
Calibration Front Panel Calibration
Auto voltage adjust Enable for improved voltage regulation within ±0.1V
MECHANICAL SPECIFICATIONS
2kVA 3kVA 5kVA 10kVA 20kVA 30kVA 40kVA
Dimensions (HxDxW) Inches 12x26x17 12x26x17 12x26x17 28x26x17 34x26x17 38x36x24 43x36x24
Weights (Kg/lbs) 60/132 65/143 80/175 200/440 315/695 465/1025 550/1210
©2003 ADAPTIVE POWER SYSTEMS, Irvine, CA, U.S.A. Subject to change without notice.
Cooling fans
Output curcuit breaker
Output connections
Input curcuit breaker
801 Hailey Street Ardmore, OK 73401
Direct: 949-752-8400 • Fax: 949-756-0838
Toll Free: 1-866-517-8400
www.adaptivepower.com
TM
APS1000-9/06
Instrument Specifications
Input connections
Casters