Owner's manual
5
A-Side Z-Side
Rx Tx
Out
In
MON
DSX-1Digital Switch Remote TerminalD Shelf
C Shelf
B Shelf
A Shelf
T-BERD Outside Plant Tester
DLC Analyzer
SLC-96 datalinkmonitor
The T-BERD Outside PlantTester can
capture major and minor shelf alarms,
far-end loopback, line protection
switches, and maintenance events in
both directions for nonintrusive,
in-service verification.
SLC-96 datalinkemulation
The user can verify central office switch
and terminal response to alarms, far-end
loopbacks, and line protection switches
as wellas execute test pair maintenance
requests during system installation
and in-service maintenance.
Two-Wire VF input/output
The T-BERD Outside PlantTester allows
a butt-set to be connected for DTMF digit
transmission, callplacement, and talk
path for subscriber maintenance and
PBX applications.
SLC-96 Mode 2 configuration timeslot
assignmentresults
The T-BERD Outside PlantTester can
determine channel and timeslot assign-
ment for systems configured for SLC-96
Mode2 concentrated applications.
Please refer to figure 4.
figure 2 Measure total length of the loop, including bridged taps,
to verify that it meets CSA standards
figure 4 Ensure remote terminal operations, verify voice-grade service,
and validate signaling transmissions during system qualifications
CO CPE
T-BERD Outside Plant Tester
CO CPE
T-BERD Outside Plant Tester
T-BERD Outside Plant Tester
figure 3 Measure signal loss to qualify loop integrity prior to circuit turn-up