user manual
AUTO SHUTOFF
If the tester is left on while in a user select mode (other than SOC) the ATD5493 will automatically shutoff
after 3 minutes from the last user entry. This will conserve battery life in case the tester is left on
inadvertently.
REPLACING THE INTERNAL 9V BATTERY
1. The ATD5493 will alert the user when the voltage of the internal battery is low and needs to be
replaced. When this occurs, the display shows REPLACE INTERNAL BATTERY. This
message will also display if no battery is installed.
2. To replace battery: Remove screw at back of tester and lift up the battery cover. Insert the 9V
battery into the battery compartment noting the polarity label inside. (See figure below).
Printing the Data on your PC Printer
To print the data using your PC printer, click on print button. The last entry will print. To print a different entry,
click on the row to highlight. The data will print out on standard 81/2 x 11 size computer paper.
Header information is entered in
Setup (see page 3)
Date and Technician
(see page 4)
Car information entered
(see page 4)
Data from battery tester
ATD5493
Battery
Compartment
TRANSMITTING/ RECEIVING ERROR MESSAGES
1. If remote is turned on when local transmitter is not connected the display will show:
“WAITING TO CONNECT”
2. If remote is temporarily out of range or signal is momentarily weak the display will show:
“SYNCING”
“PLEASE WAIT”
3. If local transmitter becomes disconnected or remote cannot sync after several unsuccessful attempts and
reconnection is not possible, the display will show:
“WAITING TIME OUT”
“GOODBYE”
NOTE: To properly test the Electrical System
(Full Test) the test sequence should be Battery
Test, Starter Test, and then Charging System
Test. The battery must be in good condition to
properly test the Starter and Charging system.
Therefore, the Starter Test Data and/or Charging
Test Data may not show on the printout if either
test is skipped.
6