user manual

INTRODUCTION
The
ATD5493 Wireless Battery System Tester tests all 6V and 12V lead acid batteries individually or in parallel and series battery
packs.
The tester will display the battery or battery pack condition as % available capacity, rated capacity (i.e. CCA’s), state of
charge voltage and good, marginal
or replace status. The ATD5493 also tests 12V, 24V and 36V starter and charging systems
including
starter draw, alternator output (loaded/unloaded), and diode ripple.The ATD 5493 features a Radio wireless printer
output for remote printout of the test results. Test results can be sent to a USB Adapter (included). The test data for the l
ast test
perfor
med is stored in the memory and can be reviewed either when connected to a battery, or when disconnected from the
battery at a later time.
Features:
Patented conductance technology
Displays % of capacity and CCA’s.
Tests all 12V lead acid batteries including AGM and Gel
Includes Wireless Local Transmitter
Radio printer interface for remote printing
USB adapter for PC printing (included)
No conversion tables needed
Test batteries from 100 CCA to 3500 CCA (battery pack)
Tests 6/12/36V Starting/Charging Systems
Tests both series and parallel batteries
Tests Alternator Ripple
Bad cell is detected and displayed
Displays Multiple International Units
Tests 6V batteries
Custom Header with Company Name, Date and Time
Loose lead detection
Temperature Compensation
RoHS compliant brass post adapters included
Multiple language (English, Spanish, French)
Reverse polarity protection
Auto shutoff feature
Made in USA
1
Local Transmitter
Local Transmitter will power on
and automatically begin
transmitting data when
connected to battery.
ATD5493 Controls
Press MENU ON and HOLD until display reads WAITING TO
CONNECT for PRINT or REVIEW. Press Menu again to turn
OFF.
2-line 16 character LCD display:
Prompt symbols: + (UP/NEXT)
- (DOWN/BACK)
(ENTER)
Press + to scroll UP or
Press to ENTER
Radio
Press - to scroll DOWN or
To Setup in Utility Menu: Press MENU and hold down +.
NOTE: Press and hold
UP/NEXT button while turning
on unit to enter “Setup” mode.