ATD‐5200 18 GALLON SELF‐EVACUATING OIL DRAIN INSTRUCTION MANUAL SPECIFICATIONS: Model: Min Height: Max Height: Bowl Depth: Bowl Diameter: Tank Capacity: Max Air Pressure: ATD‐5200 46” 76” 5.
General Safety Warnings: WARNING: The instructions and warnings contained in this manual should be read and understood before using or operating this tool. Do not allow anyone to use or operate this tool until they have read this manual and have developed a thorough understanding of how this tool works. Failure to observe any of the following instructions could result in severe personal injury to tool user and bystanders, or cause damage to the tool and property.
WARNING: Always use air hose and couplings with a minimum working pressure rating of at least 1‐1/2 times the maximum working pressure rating of the tool. WARNING: Do not depress the tool trigger/lever when connecting the air supply hose. WARNING: Do not lock, tape, wire, or otherwise disable the “ON/OFF” valve in the “ON” position. The trigger must always be free to return to the “OFF” position when released.
WARNING: MAX Pressure – 7 psi. Never pressurize tank with ball valve open. If used oil does not evacuate tank upon pressurization, check that ball valve is fully closed (handle in horizontal position). If this does not correct the problem, remove the unit from service and contact an authorized service center for repair. If the pop‐off valve relieves ANY air pressure from the tank, remove the unit from service and contact an authorized service center for repair.
Operating Instructions: TO DRAIN OIL: With valve fully open (Valve handle in vertical position), raise drain bowl to desired height and lock in place. Drain oil into bowl/tank assembly. Check sight gauge tube on back side of tank frequently. DO NOT fill tank above maximum oil level as shown. TO TRANSPORT TANK With valve fully open (valve handle in vertical position), lower drain bowl to desired height. Always use the tank handle to transport the tank assembly.
TO EVACUATE OIL Evacuate used oil from tank when maximum oil level is obtained. DO NOT fill tank above maximum oil level as indicated above. Raise drain bowl and lock in place, close valve fully (valve handle in horizontal position), and place nozzle SECURELY into used oil collection reservoir. Connect air to inlet nipple and discharge oil. MAXIMUM AIR PRESSURE – 7 PSI. Never leave unit unattended when evacuating oil.
ATD-5200 ITEM# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ORDERING PART# PRT5200-01 PRT5200-02 PRT5200-03 PRT5200-04 PRT5200-05 PRT5200-06 PRT5200-07 PRT5200-08 PRT5200-09 PRT5200-10 PRT5200-11 PRT5200-HK PRT5200-HK PRT5200-14 PART DESCRIPTION FUNNEL ASSEMBLY DRAIN TUBE 4” NIPPLE KNOB HEX BUSH 1/4" BALL VALVE 1-1/2" BALL VALVE TUBE CONNECTOR HEX CONNECTOR HANDLE BLEEDER VALVE SCREW LOOP CLAMP HOSE/NOZZLE ASSEMBLY ITEM# 15 16 17 18 19 20 21 22 23 24 25 26 27 ORDERING PART# PRT5200-15 PRT5200-HK PRT5200-17 PRT5200