User manual

INSTALLATION
WARNING! Refer to Safety
chapters.
Building In
Securing the appliance to the
cabinet
1. Open the appliance door.
2. Fasten the appliance to the cabinet.
3. Put the four distance holders (A) into the
holes in the frame and then tighten the
four screws (B) supplied with the
appliance.
A B
Electrical installation
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied with a main plug
and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also
refer to the table:
Total power (W)
Section of the ca-
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
20