Operation Manual

GB 24
Electrical connectionINSTALLATION INSTRUCTIONS
3 phases with 1 zero connection (3 1N, 400 V ~ / 50 Hz):
º The voltage between the phase and the zero is 230 V ~.
The voltage between the two phases is 400 V ~.
Fit a connecting bridge between connecting points 4-4. Phase
3 carries no load. The groups must have fuses of at least 16 A
(3x). The core diameter of the connecting cable must be at least
2.5 mm
2
.
4 3 2 1
3L 1N a.c. 400V / 50 Hz
appliance
internal
generators
right
generators left
2 phases with 1 zero connection (2 1N, 400 V ~ / 50 Hz):
º The voltage between the phase and the zero is 230 V ~.
The voltage between the two phases is 400 V ~. If there is not
a voltage of 400 V ~ between the phases, two wires have
been taken from the same phase in the meter cupboard
and the hob must be connected with two neutral wires, as
indicated under 2 phases with 2 neutrals. Fit a connecting
bridge between connecting points 3-4. The groups must have
fuses of at least 16 A (2x). The core diameter of the connecting
cable must be at least 2.5 mm
2
.
4 3 2 1
2L 1N a.c. 400 V / 50 Hz
appliance
internal
generators
right
generators left