Operation Manual

EN 32
Gas information
G25/25
mbar
G20/20
mbar
G25/20
mbar
G30/29
mbar
G31/29
mbar
G31/36
mbar
G30/50
mbar
G31/50
mbar
G31/67
mbar
Burner-
type
(kW) (kW) (kW) (kW /
g/h)
(kW /
g/h)
(kW /
g/h)
(kW /
g/h)
(kW /
g/h)
(kW /
g/h)
Simmer 1.00 1.00 0.90 0.90 / 65 0.79 / 57 0.90 / 65 1.00 / 72 0.88 / 63 1.00 / 72
Semi-
rapid
2.00 2.00 1.80 1.60 /
115
1.41 /
101
1.60 /
115
2.00 /
144
1.76 /
127
2.00 /
144
Rapid 3.00 3.00 2.70 2.30 /
166
2.02 /
146
2.30 /
166
2.70 /
194
2.38 /
171
2.70 /
194
Wok 4.50 4.50 4.50 3.50 /
252
3.08 /
222
3.50 /
252
4.00 /
288
3.52 /
253
4.00 /
288
Setting up the appliance for other gas
This appliance has been set up for natural gas (G25/25 or G20/20).
The appliance can be set up for other gas types and pressures by
means of a conversion kit. You can order the kit from the sales and
service organisation. The conversion instructions are supplied with
the kit.
INSTALLATION INSTRUCTIONS