Operation Manual

GB 15
fitting the upper telescopic pipe
Fix the plugs and threaded ends in the ceiling. Screw two
nuts onto the threaded ends in the opposite direction. Screw
the threaded ends into the plugs in the ceiling, leaving 20 mm
projecting.
Remove the nuts.
Place the upper telescopic pipe over the threaded ends. Put
the washers on and tighten the nuts.
mounting socket
Slide the mounting socket into the upper pipe until the
bottom edge is at the correct distance from the worktop (see
illustration).
Dimension A Futura 278 mm
Dimension A Linear 236 mm
Fasten the mounting socket using the four bolts (M5 x 12),
washers and nuts M5.
assembly (continued)
20
A
650
A
650
GB 14
assembly (continued)
fitting island models
The most important dimensions are given above. You can
adjust the height of the telescopic pipe, but bear in mind the
permitted tolerances.
Position the discharge and the electrical connection in such
a way that it will be easy to hook up the hood.
marking
Mark the holes to be drilled on the ceiling by means of the
stencil.
Drill the holes (4 x 10 mm).
building-in dimensions island hood
¿150/125
700
1000
250
240
150
800-1025
min. 650
¿150/125
750-975
242
1000
min. 650
700
252
60
EG3/4/8U
EG3/4/8V