User`s manual
.
UL Programming Requirements
Table 3-l indicates programming areas where UL requirements dictate specific program settings for
Underwriter’s Laboratories (UL) Listings (columns are for different UL Listings). If no entry, the function is
optional. Items underlined show where the system’s default setting is inconsistent with these UL require-
ments.
Table 3-l
UL
Programming Requirements
Fn#
113
121
124
211
212
213
215
216
233/243
234/244
236/246
311
313
315
321
411 thru 414
514
517
518
520
612
614
615
71
l/721/724
7221725
727
821
Description
Reporting
Delay Trbl?
Exit Delay
Dial Type
Dial Delay
Tone Wait
Retry Dly
GndStart
Msg.Fmt.:
Rcvr.Fmt.:
Listen in
Restoral Rpt.
AC Pwr
Rpt
Suspend Rpt.
O/C
Rpt
Close Beep
ass
Rpt.
Rypss Rstr Opt..
See Table 3-4
Priority Snsr
Wrls Supervs.
Entry Delay
Bypass Group
AutoForceArm
AutoSwingBypss
Perm.Bypass
Siren Cadences:
Siren Delays:
Siren Timeout
Keypad number:
Note 1: UL Commercial includes UL365 (burglary-police),
UL609
(burglary-local),
UL1610
(burglary-central station), and
UL1635 (digital communicators).
Note 2:
(Fn#211,212,213)
Must report the alarm within 90 seconds, maximum.
Note 3:
(Fn#517)
Supervise “permanent” mounted devices, do not supervise portable devices.
Note 4:
(Fn#518)
For
UL1635,
must be 45 seconds maximum.
Note 5: UL1637 requires medical (Emergency) to have priority over Burglary. Program with 711 (I), 721 (0), and 724 (0);
siren cadence matches keypad cadence.
Note 6: Underline signifies an area where defaults differ from UL requirements.
i.-
3-24
AT&T Security System 8300 Installer’s Manual
UL Commercial Res Medical Res Fire
Note 1
Res Burg
UL1637 UL985
UL1023
(1) Mon. Svc.
(1) Mon. Svc.
(0) Don’t
(0) Don’t
(0) Don’t
(0) Don’t
60 Sec. max.
60 sec. max.
Note 2 Note 2
Note 2 Note 2
3-5 Sec.
3-5 sec.
45 Sec. max.
45 sec. max.
45 sec. max.
(0) Don’t use (0) Don’t use (0) Don’t use
Don’t use
Match the monitoring service equipment and requirements
Match the monitoring service equipment and requirements
(0) don’t
(1)
day
(3) Normal
(1) do
(1) do
(1) do
(1)
yes
(1)
yes
na
Note 3
(1)
yes
Note 3
X-60 sec.(Note 4)
45 sec.max.
(0) no
(0) no
(0) no
(0) no
(0) no
(0) no
(0) no
(0) no
(0) no
(0) no
Burglary, Fire,
&
Medical must each be different. Note 5.
0
(15) minimum
(5) minimum (4) minimum
(4) minimum
At least 2 total (1 must be control/display type), maximum of 5.