317 Event History Report Option
#
0= Don’t dump event history to monitoring service (to AT&T FSK
receiver only) when full (60 of possible 64 events), and don’t
dump event history in the event of Suspending Operation;
1=
Do.
318 Opening/Closing Report Option
#
319 Closing Report Audible
#
320 Bypass Report Option
#
NOTE: The history buffer is maintained whether this option is 0
or
1,
and can be interrogated from CCUBOSS. Up to 64 events
are kept, with the oldest being lost when a new event occurs,
0= Don’t report OPEN or CLOSE;
1 = 1 =
Do report whenever status
change from “AWAY” or to “AWAY”
0= Don’t sound siren (only, not keypad) beep when monitoring
service acknowledges closing; 1= Do.
0= Don’t reoort bypassing a sensor,
1=
Do.
NOTE: Permanent bypasses are only reported at creation and
removal.
i
\-
321 Bypass
Restoral
Report Option
#
0= Don’t report bypass restoral, 1 = 1 = Do (if allowed by
Fn#320).
===============400
Series:
Categories
1= Entry/Exit
5= Interior Tamper
9=
Silent Panic
13=
Trouble Category
2=
Perimeter
6= Day Zone
10= Fire
14=
Auxiliary(
1)
3= Interior
7= Non-Alarm
11=
Emergency
15=
Auxiliary(2)
4= 24-Hour/
8= Audible Panic
12=
Environmental
16=
Keyswitch
Perimeter Tamper
0=
Off
1=
Delayed
RESPONSES
2= Instant
3= Follower
4= Warning Tone
5= Chime (keypad DipSw#4 must be ON)
411 OFF Action Mode Assignment
16#‘s
For each of the 16 above Categories (in the order described
above) enter a number
(0-5),
describing what the response
should be to an alarm for that category, with the system in the
OFF mode. Enter
“0”
for unused categories. Example (Default):
0002 2452 2222 2002 (spaces added to make reading numbers
easier) sets all categories Off except 4, 5, 8-13, are Instant; 6
(Day Zone) is Warning Tone; and 7 (Non-alarm) is Chime. Table
3-2 (after this listing) shows all default settings.
412 DAY Action Mode Assignment
16#‘s
413 NIGHT Action Mode Assignment
16#‘s
For each of the 16 above categories (in the order described
above) enter a number
(0-5)
describing what the response
should be to an alarm for that category, with the system in the
DAY mode. Enter
“0”
for unused categories. Default: 1203
2452 2222 2002 (spaces added to make reading numbers
easier). See Table 3-2.
For each of the 16 above Categories (in the order described
above) enter a number
(0-5)
describing what the response
should be to an alarm for that category, with the system in the
NIGHT mode. Enter “0” for unused categories. Default: 2222
2252 2222 2222 (spaces added to make reading numbers
easier). See Table 3-2.
(.
AT&T Security System 8300 Installer’s Manual