219 Modem Call Number
16#‘s
220 Modem Carrier Detect Delay
2#‘s
221 Number of Incoming Rings
2#‘s
230
Series:
Receiver
1
231
Rcvr 1 Phone Number
16#‘s
232
233
234
Rcvr 1 Account Number
6#‘s.
Rcvr 1 Message Format
#
Rcvr 1 Receiver Protocol Format
#
235
Communicator Message Codes
15chrs
Enter the phone number where your computer will be, while it is
remote programming. (The CCU must call back to the modem
at that number as part of the connection process.) Default=
If empty, remote programming is not possible and CCUempty.
will not listen for calls from CCUBOSS. Enter a star (*) to empty,
if there is a number in this space.
NOTES: Temporarily disable the Call Waiting option, if there is
one (star-7-O may work, refer to local phone service provider).
Use
“#”
for a pause, if required for dialing out. Remember
leading l’s and area codes, as required.
0-15
When reporting (SIA or AT&T FSK), modem spends how
many (10
sec)
periods trying to detect the carrier signal from the
device on the other end of the line?
Default 3
(30 seconds).
1-15BAllow how many incoming rings before the modem
answers the call to check for CCUBOSS.
Enter the (monitoring service) phone number for the dialer to
call, up to 16 digits.
NOTES: For phones with the Call Waiting option, the
“*70”
may temporarily disable the Call Waiting, check with the service
provider. The
“#”
is a pause, if needed for business PBX phone
systems. To prevent dialing out, enter a single
“*”
(which
removes the phone number). Remember leading l’s and area
codes, as required. No default
Account number assigned by Monitoring Service. Use leading
zeros for numbers smaller than 100,000. 000000
1=
3/1(4/1
) format;
2=
3/1
(4/1)
Extended, 3= 4/2 format,
4=
4/9
format (requires DTMF protocol,
Fn#234)
see Figure 3-5.
1=
Slow A;
2=
Fast A; 3= Slow B; 4= Fast B; 5= Sumcheck
2300; 6= Sumcheck 1400;
7=
DTMF; 8=
SIA(FSK);
9= AT&T
(FSK). See Receiver Compatibility chart, at the end of this
chapter.
Enter a string of numbers and characters, (0,
1,
2, 3, 4, 5, 6, 7,
8, 9, A, B, C, D, E, F, one for each message) that the monitoring
station will understand to mean each of the following messages.
A 0 (zero) means that the message will not be sent. Enter the
data in the order below: Defaults follow
descriptions.
[15chrs
means to enter fifteen characters (alpha or numeric,
refer to Fig.
3-1)]
-
*the “number”to send to indicate Intrusion-Perim, Entry/Exit,
24-Hr/Perim
Tamper, Day Zone 1
-
[*]the “number” to send to indicate Interior Intrusion, and Interior Tamper
2
-
[*]the “number” to send to indicate Silent Panic
3
-
[*]the
“number” to send to indicate Audible Panic
4
-
[*]the “number” to send to indicate Fire 5
3-14