122 Length of Short Delay
123 Length of Long Delay
124 Length of Exit Delay
125 Telephone Option
126 Intercom Option
#
Enter O-9.
(0=10,
1=20,
2=30,
3=40, 4=50, 5=60, 6=120,
7=180, 8=240, 9=300 seconds) Set this once for entire system.
(Used by
Fn#
124,518, 722/725)
#
Enter O-9.
(0=10,
1=20,
2=30, 3=40, 4=50, 5=60, 6=120,
7=180, 8=240, 9=300 seconds) Set this once for entire system.
(Used by Fn# 124,518, 722/725)
#
0=No
delay; 1 =short delay; 2=long delav.
NOTE: This
Fn#
overrides the settings for the 400 Series Entry/
Exit Category.
#
0= Don’t have keypad used as a phone.
1=
Do
#
0= Don’t allow keypad to be used as an intercom.
1=
Do use
keypad as an intercom.
================200 Series: Communications
210
Series: Modem and Dialer
211 Touch Tone or Pulse Dial
212 Dialer Delay
7#‘s
213 Dial Tone Wait
214 Dialing Interdigit Pause
215 Retry Delay
216 Ground Start Option
217 Two-line Phone Line
218 Local Phone Test Option
#
2#‘s
#
3#‘s
#
#
#
0=
Pulse,
1=
Touch Tone. The selected dialing method will
become the default for all types of dialing within the security
system (including keypad use as a telephone). User menu can
select TT temporarily during use, with a “*“.
0-9. How many (10 second) periods to wait between alarm and
placing the call (default. 0 interval). Specify for each of the first
7 channels defined in
Fn#235.
1-16. How many seconds to wait for dial tone detect (default, 4
sec) before dialing anyway. (The dialer will first try 3 times to
get the dial tone, before resorting to the “dial anyway” option.
1 or 3. How many seconds long shall a dialing “pause” be?
(default. 1
sec).
The
“#"
stands for a pause, when entering a
number to be dialed.
5-260 Wait how many seconds after failed call before retry.
Default. 10 seconds. UL maximum =45 seconds.
1=
Enable ground start, needed for phone interface in many
private business exchanges; 0= Disable.
0= Disable (only 1 line)
1=
enable (alternates between lines
after calling out failure):
0= Disable the checking of the local phone line every hour
(Trouble after 12 consecutive Failures
); 1 = Enable (checks both
lines if Fn# 217 is “1”).
AT&T Security System 8300 Installer’s Manual
3-13