User`s manual

Programming Options-Long Version
NOTES:
1.
If a condition is underlined in the “Explanation” column, that underline signifies the default setting from
the factory.
2.*
A
“#”
under Entry Format means that a number (O-9) must be entered there; “4#‘s” means that up to four
numbers (digits) can be entered.
3.
A
“chrs”
means that characters (numbers or letters) can be entered; “16chrs” means that up to sixteen
characters may be entered (eg., “2nd floor bath”).
3.
Normally, a “0” will select the OFF/DISABLED/NO condition and a “1” will select the ON/ENABLED/YES.
4.
Data for the sensors (Function Number 511-521) is likely to be entered in a “loop.” Appropriate use of
the NIGHT key will make this a more convenient operation (see Figure 3-2).
5.
“Function Number” will be shortened to
“Fn#”
in the Programming Lists.
Before you can program the system, you must enter the Master Installer Code at the request for Access
Code. Press the pound
(#)
followed by the default six-digit number-the default number for this system is
“999999.” Change this number (use
Fn#
111) to provide your dealership with secure control of the system.
Funct
Numb.
Title
Entry
Format*
Explanation
================OOO
Series: Installer Tests
011 Siren test
#
0= Sirens OFF;
1=
Siren 1 ON; 2= Siren 2 ON. Press
“0,““1
,"
or
“2” as desired and the sirens will turn ON or OFF. When done,
press “0” then press SELECT to exit.
012 Relay test
#
0= Relays OFF;
1=
Relay 1 ON; 2= Relay 2 ON. Operates like
siren test; press
“0”
and SELECT to exit.
013 X-10 module test
#
0= All OFF; 1-8 turns corresponding unit ON. Like sirens and
relays; press “0” and SELECT to exit.
014 Verification Test #
In this mode, the system doesn’t provide any alarms or report to
the monitoring service. The CCU monitors each sensor viola-
tion, beeps the keypads in response, and keeps a log of tested
sensors. View the log at a keypad by pressing the [SELECT]
button. Exit the Test by selecting
<
or
>>.
Only 1 keypad may
be in Test mode at a time.
[Underline shows Default setting]
[# means enter one-digit number]
================100
Series:
System
Setting
110 Series: System Programming
111 Set Installer Keypad Code
6#‘s
6-digit code required for local (keypad) programming access,
Default 999999, This code must be entered by any service
person before doing on-site programming.
[6#‘s
means to enter six digits]
AT&T Security System 8300 Installer’s Manual 3-11