Instruction manual

FEATURES AND SERVICES
Administration Requirements
System (Pooled Modems):
Modem Request Code (1-9999; default = 820). Allows users to indicate a need for a
conversion resource on a data call originated at an analog data endpoint.
Receiver Responds To Remote Loop (yes or no; default = yes). When active, Data
Set Ready is asserted when the modem is in an analog loop test mode.
Disconnect On Loss Of Carrier (yes or no; default = yes). When active, a loss of the
received carrier will cause the modem to terminate the call.
CF-CB Common (yes or no; default = yes). When active, Clear to Send turns off if
Carrier Detect turns off. When a call is being established, Clear to Send and Carrier
Detect are not allowed to turn on until carrier has been received and the Clear to
Send timer has timed out.
Disconnect On Received Space (yes or no; default = yes). When active, the modem
will disconnect after receiving a “Space” signal of approximately two seconds
duration.
Send Space On Disconnect (yes or no; default = yes). When active, the modem,
upon receiving a negation of Data Terminal Ready, sends approximately four
seconds of “Space”
signal and then disconnects.
Without this option active, the
modem, upon receiving a negation of the Data Terminal Ready signal, disconnects
immediately.
Hardware Requirements
One TN758 Pooled Modem CP provides two conversion resources. Two TN758s are allowed
per system cabinet, for a total of 12 conversion resources in a 3-cabinet system.
2-232