Instruction manual

FEATURES AND SERVICES
Answering Endpoint:
When the dialed endpoint is alerted, the user receives “INCOMING CALL-”. (The called
terminal will auto-answer if it is turned on.) If the handshake succeeds, a data connection is
established and the “CONNECTED” message is displayed if so optioned. If the handshake
fails, the user receives “INCOMPATIBLE FAR END, DISCONNECTED” and the data endpoint
returns to idle mode.
Considerations
Data Terminal Dialing allows users to place data calls from their terminals using the Data
Terminal Dialing feature and allows users to review the options administered for their data
ports.
Interactions
The following features interact with Data Terminal Dialing
End-To-End Signaling: (See preceding text.)
Modem Pooling: Data calls between analog and digital endpoints require that a conversion
resource (TN758) be available.
If one is not, the “NO MODEM” followed by “TRY AGAIN”
message will be displayed.
Speed Dialing:
System Speed Dialing codes can be dialed from data terminals. Personal
Speed Dialing is not supported.
Administration Requirements
Data Port: See the table of Permissible Data Port Options in the “Command Mode” feature
description.
Hardware Requirements
TN726 Data Line CP to support each digital endpoint.
TN758 Pooled Modem CP to support data calls between digital and analog endpoints.
2-138