User`s guide

Printing Reports
Setting the Baud Rate
Contents of a Traffic
Analysis Report
You can connect a TI 700 or equivalent 1200-baud serial printer to the serial i/o
port of the SPIRIT Attendant to produce reports to analyze call traffic patterns or
to see how routes, announcement times, or business schedules are programmed.
NOTE:
A special adapter (printer cable) is required to connect a “silent 700”
printer.
The default baud rate for the serial i/o port is 9600. To connect a TI 700 or
equivalent 1200-baud serial printer, set the baud rate to 1200 using the following
procedure:
1. Select an outside line and dial a telephone number that is answered by the
SPIRIT Attendant.
2. Wait for an answer.
3. Dial followed immediately by the authorized caller code and #.
The two-beep confirmation tone sounds.
4. Dial 291712 # to change the baud rate to 1200 baud.
The two-beep confirmation tone sounds.
5. Exit authorized caller mode by dialing #.
6. To disconnect, dial #.
The traffic analysis report provides the following information:
Route
The report is detailed by route number (0 through 9).
Messages
This field is not relevant to the SPIRIT Attendant.
Attempted
This field contains the number of times outside callers have selected a
particular route since the last time the counter was reset to 0. See "Resetting
the Counters'" for details.
Completed
This field records the number of times a call was completed to a particular
route.
Abandoned before answer
This field indicates the number of calls abandoned before the SPIRIT
Attendant answered.
Abandoned after answer
The number of calls abandoned after the SPIRIT Attendant answers a call but
before the call is processed.
Authorized callers
The number of times authorized caller mode was accessed for programming.
NOTE:
If any of the report counters exceed 65,535 total, the counter is
reset to 0.
3-4
Testing and Troubleshooting