Specifications
Door Unlock
NOTE: Silent Monitor can only
be programmed if configured for
Dry Loop or Trunk Adapter Mode.
The default for this code is
[O]
[P] [E] [N] .
Silent Monitor
NOTE: If used in Station Mode,
silent monitor will cut off after
2 minutes. (The system hangs up
after 30 seconds if no activity is
detected.)
Any time you are connected to a door zone—whether in response to a
Door Bell or Door Ajar condition, or as a result of paging to a Doorspeaker
in Silent Monitor mode (see below)—you may operate the door strike plate
if one has been installed:
1. Enter the Door Unlock Code on the phone keypad.
The system will actIvate the control pair on the zone for four seconds,
or until It detects that the door has been opened and closed.
This Doorspeaker feature allows for silent monitoring of a Doorspeaker
zone:
1.
2.
3.
Make a single-zone page to a Doorspeaker zone: follow steps 1 and
2 from Paging Procedure, page 7-2.
The Pre-Announcement Tone will be suppressed. You can monitor
conversation at the Doorspeaker zone.
You can speak into the telephone transmitter, or listen to someone
speaking at the Doorspeaker zone. (One person can speak at a
time; the person speaking into the telephone will take precedence
over the person speaking at the Doorspeaker zone.)
Hang up the telephone.
Remote Amplifier Mode
Music/Page levels are adustable.
Door Bell/Door Ajar inputs are
ignored (see Figure 3-3).
Auxiliary Paging
This mode is intended for connecting a primary paging zone to a paging
amplifier. A Remote Amplifier zone provides the same paging features as
a Page/Speaker zone, except that the audio pair has a 0.655 Vrms output
(default Level 2), and the system closes the relay on the control pair when
presenting a signal (Page, Tone, or Music) on the audio pair, and opens
relay contacts when the zone is idle.
Zone
Zone 3 of the PARTNER PagePac system is called the Auxiliary Paging
Zone. This zone is intended for connection to a paging amplifier. The
audio pair provides a nominal 0 dBm signal to the audio inputs of an
amplifier. The Auxiliary Paging Zone operates in the same fashion as a
Primary Paging Zone configured in Remote Amplifier Mode, as described
above. The main difference is that Zone 3 does NOT provide Talkback or
an on-board paging amplifier. The Auxiliary Paging Zone ignores the Door
Bell and Door Ajar inputs.
7-6 Operating Procedures