Overview
At this point the PARTNER PagePac hardware should be installed as
described in Sections 2 through 5. The module should also be
programmed with factory default settings or user selections as described in
Section 6. You are now ready to use the system. This chapter describes
the procedures for operating the PARTNER PagePac system.
Primary Paging Zones
Refer to Section 6 for Zones 1 and 2 of the PARTNER PagePac system are called the Primary
programming the type of zone
Paging Zones. Each of these zones can be programmed to operate in
mode, and for descriptions and
Page/Speaker Mode, Doorspeaker Mode, or Remote Amplifier Mode.
programming of the various zone
options.
Page/Speaker Mode
Paging Procedure
A Page/Speaker Mode zone is
intended for connection to one or
more voice coil speakers.
If a Connect Password has been
enabled, you will hear a special
tone. Enter the Connect
Password
To change a factory default setting or a user-programmed setting, you
must first access the PARTNER PagePac system.
1. If you have configured your PARTNER PagePac system:
For Dry Loop Mode (connection to Page Port) you will need to dial
[INTERCOM] [7] [0] .
For Station Mode operation, you will need to dial [INTERCOM] ,
followed by the extension number connected to the PARTNER
PagePac paging system. For example, if you have configured the
PARTNER PagePac paging system with a cable connecting from the
PARTNER PagePac STN l/N port to extension 20 of a PARTNER
Plus system module, you would dial [INTERCOM]
[2] [0] the first time
you wish to access PARTNER PagePac features and programming
capabilities.
For Trunk Adapter Mode you will need to select the trunk which is
connected to the PARTNER PagePac unit by pressing the
appropriate [LINE]
button. For standard telephone access, use Direct
Line Pickup.
You will hear the PARTNER PagePac dial tone in the telephone
receiver.
2. Dial the zone or zone group to which the page is to be made:
[1]
— Zone 1
[4]
— Zones 2 and 3
[2]
— Zone 2 [5] — Zones 1 and 3
[3]
— Zone 3
[6]
— Zones 1 and 2
[7]
— All Zones
7-2 Operating Procedures