Specifications
Table 6-3 Default Settings By Zone Type
Primary Paging Zones
(Zones 1 and 2)
Zone Option
Auxiliary Zone
(Zone 3)
Page/Speaker
Doorspeaker
Remote Amp
Aux Amp
Door Action
Not supported
Door Alert (1) Not supported Not supported
Page/Tone Level
1.9 Vrms (6)
1.9 Vrms (6) 0.655 Vrms (2)
Not supported
Music Level
1.1 Vrms (4) 1.1 Vrms (4) 0.655 Vrms (2) Not supported
Station Page Enabled
Yes (1)
Note 1
Yes
(1)
Yes
(1)
Music Enabled
No
(0)
No (0)
No
(0)
No (0)
Talkback Enabled
No
(0)
Yes (1)
No
(0)
Not supported
Night Bell Enabled
Yes (1)
No (0)
Yes (1)
Yes (1)
PassDTMFtoZone
No
(0)
No (0)
No
(0)
No (0)
Microphone Page
Enabled
Yes (1) No (0) Yes (1) Yes (1)
Door Alert Enabled
Yes (1)
No (0)
Yes (1)
Yes (1)
Note 1: Default parameter setting is No (0), which causes the zone to be excluded from group pages. (Group pages are
discussed in Section 7.) However, a Doorspeaker zone may always be selected in Silent Monitor mode by performing a
single-zone page (zone number 1 or 2).
Programming Procedures
To change a factory default setting or a user-programmed setting, you
must first access the PARTNER PagePac system.
If you have configured your PARTNER PagePac system:
For Dry Loop Mode (connection to Page Port) you will need to dial
[INTERCOM]
[7] [0].
For Station Mode operation, you will need to dial [INTERCOM] ,
followed by the extension number connected to the PARTNER
PagePac paging system. For example, if you have configured the
PARTNER PagePac paging system with a cable connecting from the
PARTNER PagePac STN l/N port to extension 20 of a PARTNER
PI
US system module, you would dial [INTERCOM] [2] [0] the first time
you wish to access PARTNER PagePac features and programming
capabilities.
If a Connect Password has been
enabled, you will hear a special
tone. Enter the Connect
Password.
For Trunk Adapter Mode you will need to select the trunk which is
connected to the PARTNER PagePac unit by pressing the
appropriate [LINE] button. For standard telephone
Line Pickup.
.
access, use Direct
Programming
6-5