Specifications

Zone Programming Options
Ring Down mode only available
in Station Mode.
NOTE: Disabling for a
doorspeaker zone keeps the
zone from being selected as part
of a group, but does not prevent
it from being selected individually
(in Silent Monitor mode—Dry
Loop and Station Mode only).
Night Bell requires programming
the PARTNER Plus/II system for
Night Service. See page 6-9.
NOTE: The MLC-6 cordless
phone (and some standard
phones) cannot send continous
DTMF tones.
The door sled tone can be sent
to any zone, including zone 3.
Type of Zone —Specifies whether a primary paging zone is to be
operated in Page/Speaker, Doorspeaker, or Remote Amplifier mode.
The default setting is Page/Speaker. Setting this parameter causes all
other options for the zone to be set to the defaults for the specified
zone type. (See Table 6-3 for default settings by zone type.)
Door Action —Valid only for a primary paging zone optioned as a
Doorspeaker. Specifies the alerting action taken when the Door Bell is
pressed: Door Alert or Ring Down. The default setting is Door Alert.
Page/Tone Level —Specifies the volume of pages and tones sent to
the primary paging zone. (Available in Zones 1 and 2 only.) Settings
range from 0.5 Vrms (Level 1) through 3.4 Vrms (Level 8). Default is
1.9 Vrms (Level 6). (See Tables 6-3 and 6-4.)
Music Level —Specifies the volume of background music sent to a
primary paging zone. (Available in Zones 1 and 2 only.) Settings range
from 0.5 Vrms (Level 1) through 3.4 Vrms (Level 8). Default is
1.1 Vrms (Level 4). (See Tables 6-3 and 6-4.)
Station Page Enabled —Specifies whether the zone will be selected
when the user dials the zone number (or the number of a group that
includes the zone) on the telephone keypad. This option is disabled by
default for Doorspeaker, enabled otherwise.
Music Enabled —Specifies whether background music will be sent to
the zone when paging is not active. (Available in all zones.) This
option is disabled by default.
Talkback Enabled —Allows talkback for a primary paging zone. This
option is enabled by default for Doorspeaker, disabled otherwise.
(Available in Zones 1 and 2 only.) Talkback works only for a
single-page zone.
Night Bell Enabled —Sends the night bell tone to the zone when there
is activity on the Night Bell input. (Available in all zones.) This option
is disabled by default for Doorspeaker, enabled otherwise.
Pass DTMF to Zone- Routes DTMF tones which are entered during a
page to the zone without processing. (Available in all zones.) This
option is disabled by default.
Microphone Page Enabled —Selects the zone when contact closure of
the microphone input is activated. (Available in all zones.) This option
is disabled by default for Doorspeaker, enabled otherwise.
Door Alert Enabled —Routes the door alert tone to the zone when the
Door Bell is pressed or when Door Ajar is detected. (Available in all
zones.) This option is disabled by default for Doorspeaker, enabled
otherwise.
Programming 6-3