Specifications

Connecting Speakers
NOTE: Use Voice Coil speakers
only.
Paging
Area
Mounting
Location
Speaker Type
(Voice Coil)
AT&T
Order No.
NOTE: In some situations you
may be able to extend a run
farther than 600 feet, by using
fewer speakers and/or larger
diameter wire.
NOTE: Listed speakers are
capable of Talkback.
Front/Back
Door*
NOTE: Speaker quantities to the
right DO NOT apply to Zone 3,
which can drive a remote
amplifier which is only limited by
the amplifier power output
(wattage).
NOTE: 4 watts are available per
zone.
Standard voice coil ceiling speakers (indoor ceiling-type or P-Tec) and
horn speakers may be used with the PARTNER PagePac module. Use
only voice-coil 3.4 Vrms type speakers and use only the appropriate model
speaker for your situation (see Table 3-1). It is important not to exceed the
number of speakers or speaker run length maximums shown in Table 3-2
below.
Table 3-1 Recommended Speakers
Open or Closed
On Wall or Ceiling
Universal Cabinet
PEC 5330-105
Office Areas,
Conference
or
P-TEC
PEC 5330-100
Room, Etc.
Above Ceiling
Recessed Ceiling
PEC 5330-215
or P-TEC PEC 5330-100
Universal Cabinet
Hallways
On Wall or Ceiling
PEC 5330-105
Private Office
Placed on Desk
Desktop
PEC 5330-110
On Wall
Door Speaker
PEC 5330-120
Open Industrial
On Wall or Pole at
Area or
Least 15 ft. Above
1 Watt Horn
Outdoors
PEC 5331-100
Ground
w/ taps
*NOTE: Doorspeaker cable runs should use the “Home Run” method and should not
exceed 1500 feet.
Table 3-2 Speaker Limitations
PARTNER PagePac
Paging Systems
Standard
Indoor Speakers
Per Zone
(Zones 1 and 2)
Horn Speakers Per
Zone
(Zones 1 and 2)
Total Speakers
12
3 to 16**
Speakers Per Run*
4
1
Maximum Length of Speaker Run
(24 AWG Copper Wire)
600 Feet
300 Feet
*A run is a line of one or more speakers that connects directly to PARTNER PagePac
module. If using both horns and standard speakers, each horn counts as four standard
speakers.
**Depends on 1-Watt Horn Speaker tap settings - see documentation provided with
speaker.
3-4 Page/Speaker Mode Installation