Specifications
Specifications
Table 1-1 PARTNER PagePac System Specifications
Capacities
PARTNER PagePac
■ Three-zone paging, doorspeaker, and AUX amp modes
■ Compatible with AT&T PARTNER Plus and PARTNER II Communications systems
Dimensions and
PARTNER PagePac
11 “(D) x 17’’(H) x 1.5’’(W) or
4.8 lbs or
Weights
27.9 cm x 43.2 cm x 3.8 cm
2.2 kgs
Electrical
■ Door Latch: rated at
■ Contact Closures: Remote Amp = 1 amp contacts
Specifications
1 amp
Door Latch contacts rated at 1 Amp 120 VAC/50 VDC
■ Primary Paging
■ Talkback Sensitivity: with 500 µVrms, 1 KHz, at spkr leads.
Output 4-watts per
Compression threshold: -17dBm (measured at tip and ring)
channel
■ AUX Port Output: ■ Electrostatic Discharge: per Bell Publication 48002,
0dBm
Section 3.3.2.5
Extension Jack
■ Ringing voltage: +5 VDC, -140 VDC peak-to-peak; trapezoidal wave shaping
Specifications
(PARTNER
■ Talk battery: 35 to 38 Volts
System)
■ Ringing frequency: 20 Hz
Environmental
■ Mount on a wall or study, level surface at least 2 feet (0.6 meters) from the floor. For
Requirements
ventilation, wall mounting is required for 2-module systems (strongly recommended for
1-module systems)
■ Locate within 5 feet (1.5 meters) of an electrical outlet not controlled by a switch and within 5
feet (1.5 meters) of the network interface jacks, when using supplied 7-foot (2.1-meter) cords
■ Operating temperature 32” to + 104°F (0° to +40
o
C), not in direct sunlight
■ Humidity 15%–90%, noncondensing
■ For proper ventilation and easy replacement of modules, provide at least 1 foot (0.3 meters)
clearance at the top and sides and 2 feet (0.6 meters) at the front and bottom.
■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
■ 90-130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps
Requirements
■ Outlet must not be controlled by an on/off switch
■ Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation
material and thickness to the grounded and ungrounded branch circuit supply conductors,
except that it is green with or without one or more yellow stripes, is to be installed as part
of the circuit that supplies the product or system.
B. The ground conductor mentioned in item A is to be connected to ground at the service
equipment.
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be
connected to earth ground at the service equipment.
Local Phone
■ Jack type: RJ11C and RJ-45
Company
Information
■ Loop start and Dry loop lines
■ FCC Registration Number: Pending
Overview 1-5