Installation guide

Programming Quick Reference Chart
To Enter the
(1) dial the PagePac Plus system access extension
Programming Mode
(2) enter the connect password (if any)
(3) press [
* ] [ * ] and enter your programming password (if optioned)
Chart 1. System Configuration Options
Feature
Mode Option/
Verify
Dial
Listen
For
Choose Option
Listen
For
Default
To Select
To Select
To Verify
Reset to Factory
Defaults
10
20
21
Double
Beep
Enter 25327 to reset.
Enter any invalid number
string to escape.
Triple
Beeps
25327
(CLEAR)
Number of Zone
Map Digits
Double
Beep
2 (digits)
3 (digits)
4 (digits)
Triple
Beeps
2
Connect
Password
To Select
To Verify
30
31
32
33
Double
Beep
Double
Beep
Enter Password, enter # to
terminate the string.
Triple
Beeps
None
To Select
To Verify
Triple
Beeps
**
On
On
Initial and
30 sec.
Programming
Password
Enter Password, enter # to
terminate the string.
Triple
Beeps
Triple
Beeps
Confirmation Tone
To Select
To Verify
40
41
42
43
Double
Beep
0 – Off
1 – On
Pre-Announcement
Tone
To Select
To Verify
Double
Beep
0 – Off
1 – On
Talk-back
Warning Tones
To Select
To Verify
44
45
50
51
Double
Beep
0–Off
1 – Initial
2 – Initial and 30 sec.
Triple
Beeps
To Select
To Verify
Double
Beep
Enter Duration
0 – Off
1 – 10 sec.
2 – 20 sec.
3 – 30 sec.
4 – 40 sec.
5 – 50 sec.
6 – 60 sec.
Triple
Beeps
30 Sec.
Computer
Monitor
VOX Timer
Disconnect
Computer Monitor
To Select
To Verify
52
53
Double
Beep
0 – Computer Monitor
Triple
Beeps
Triple
Beeps
AA – Off
T/R – Off
N.B. – Off
Input Computer
Monitor
To Select
To Verify
54
55
Double
Beep
0 – AA Off
1 – AA On
2 – T/R Off
3 – T/R On
4 – N.B. Off
5 – N.B. On
NOTES:
Exit the programming mode by dialing #
The # key will terminate a digit string (i.e., Password string)
Programming The Controller 2-37