Installation guide

Audio Routing
Door Service
Programming Steps
If optioned, whenever a selected input zone with "Audio Source Enabled"
is active, the audio source (either Telephone Access or Attendant Access)
will be routed to the selected zone or group. The default for this
parameter is NO ZONES.
The primary use for this feature is to allow the PagePac Plus to be used
for door service. For example, you have optioned the doorbell input zone
to enable Telephone Access, and you wish now to select the door speaker
to be the output zone for this Telephone Access audio.
The audio path will remain routed for 10 seconds. If the user accesses
the controller during the 10 second period, they will automatically be
routed to the zone specified in this procedure. If the user accesses the
controller after the time expires, the user will receive a dial tone.
If a Connect password has been installed in your system, you will have to
access the PagePac Plus and enter your password, before being
automatically routed to the zone..
If the doorbell input has a higher priority than the telephone access and is
activated while telephone access paging is underway, then you will receive
the tone specified in the option "Tone Selection," above, and then will be
automatically routed to the proper zone.
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
#
].
1.
Dial [
9
] [
8
] to select Audio Routing.
Hear DOUBLE beeps.
2.
Enter the input zone number. Use ALIAS numbers, if optioned.
Otherwise, use Physical zone/group numbers.
Hear DOUBLE beeps.
3.
Enter the output zone / group ALIAS number.
Hear TRIPLE beeps.
To verify your selection, dial [
9 ] [ 9 ] and repeat steps 2 and 3 above.
Table 2-25 summarizes the Audio Routing actions.
Table 2-25. Audio Routing
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Audio
To Select
98
Double
Enter the input
Double
Output zone/
Triple
None
Routing
To Verify
99
Beep
zone number.
Beep
group number.
Beeps
Programming The Controller
2-35