Installation guide
Night Bell Enable
This is an individual zone output parameter. The choice is YES/NO with
the default being NO. With this parameter set to YES, night bell will be
sent to selected outputs whenever ring voltage is present on the night bell
input (from the PBX to the controller).
If a closure is required to trigger the night bell, then a zone will need to be
configured as an input to send night bell to designated zones when a
closure is present. This is discussed in Tone Selection and Tone Routing,
below.
Programming Steps
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ].
You will need to repeat this procedure for each output zone that you wish
to receive the night bell signal.
1.
2.
3.
Dial [
7
] [
8
] to select this option.
Hear a DOUBLE beep.
Enter the zone number, of the zone you wish to configure. Use
ALlAS numbers, if optioned. Otherwise, use Physical zone/group
numbers.
Hear a DOUBLE beep.
Enter [
0 ] for NO (Not Enabled) or enter [ 1 ] for YES (Enabled)
Hear TRIPLE beeps.
to verify the status of Might Bell Enable for a given zone, dial [
7 ] [ 9 ] and
repeat steps 2 and 3 above.
These actions are summarized in table 2-20.
Table 2-20. Night Bell Enable
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Night-Bell To Select
78 Double
(Z)
Double
0–No
Triple
NO
Enable
To Verify
79
Beep
Beep
1 – Yes
Beeps
2-28 Programming The Controller