Installation guide

Talk-Back Enable
This is a zone output parameter that enables talk-back capability for a
selected output zone or group. The choice is YES/NO, with the default
being set to NO.
All speakers in a zone or group will be active 2-way speakers if talk-back
has been enabled for a zone. See discussion of talk-back in the
Application Notes, at the end of this guide.
Programming Steps
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You will need to repeat this procedure for each output zone or zone group
that you wish to have talk-back.
1.
Dial [
7
] [
6
] to select this option.
Hear a DOUBLE beep.
2.
Enter the zone number, of the zone or group you wish to configure.
Use ALlAS numbers, if optioned. Otherwise, use Physical
zone/group numbers.
Hear a DOUBLE beep.
3.
Enter [
0 ] for NO (Not Enabled) or enter [ 1 ] for YES (Enabled)
Hear TRIPLE beeps.
To verify the status of Talk-Back Enable for a given zone, dial [
7 ] [ 7 ] and
repeat steps 2 and 3 above.
These actions are summarized in table 2-19.
Table 2-19. Talk-Back Enable
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Talk-Back To Select
76
Double
(Z,G)
Double
0 – No
Triple
No
Enable To Verify
77
Beep
Beep
1 – Yes
Beeps
Programming The Controller 2-27