Installation guide

Page Enable
Programming Steps
This output zone parameter enables paging for a selected output zone or
zone group. The choice for this selection is YES/NO, with the default
being YES. If you make an all-call page and this option is selected NO in
either a Zone Group or Individual Zones, then an all-call page will be made
to all other zones except the ones specified. If the decision is NO for the
All-Call zone and an all-call page is made, then an error tone will be
returned to you.
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ].
You will need to repeat this procedure for each output zone or zone group.
1.
2.
3.
Dial [
7
] [
4
] to select this option.
Hear a DOUBLE beep.
Enter the zone number, of the zone or group you wish to configure.
Use ALlAS numbers, if optioned. Otherwise, use Physical
zone/group numbers.
Hear a DOUBLE beep.
Enter [
0
] for NO (Page Not Enabled) or enter [
1
] for YES (Page
enabled)
Hear TRIPLE beeps.
To verify the status of Page Enable for a given zone, dial [
7 ] [ 3 ] and
repeat steps 2 and 3 above.
These actions are summarized in table 2-17.
Table 2-17. Page Enable
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Page
To Select
72 Double
(Z,G) Double
0–No
Triple
Yes
Enable To Verify
73
Beep
Beep
1 – Yes
Beeps
Programming The Controller 2-25