Installation guide
Programming Steps
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ].
You will need to repeat this procedure for each output zone.
1.
Dial [
7
] [
0
] to select this option.
Hear a DOUBLE beep.
2.
3.
Enter the zone number, of the zone you wish to configure. Refer to
your Zone Map (table 1-2). Use ALlAS numbers, if optioned.
Otherwise, use Physical zone/group numbers.
Hear a DOUBLE beep.
Enter the code for the type of output you wish to select:
[
0 ] selects AUDIO/N.O. (Normally Open)
[
1 ] selects Momentary Open
[
2 ] selects N/C (Normally Closed)
[
3 ] selects Sys HS (System Handshake)
[
4 ] selects Toggle
Hear TRIPLE beeps.
To verify the Type of Output assignment, dial [
7 ] [ 1 ] and repeat steps 2
and 3 above.
These actions are summarized in table 2-16.
Table 2-16. Type of Output
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Type of
Output
To Select
To Verify
70
71
Double
Beep
(Z)
Double
Beep
0 – Audio/N.O.
1 – Mom.Open
2 – N-C
3 – Sys HS
4 – Toggle
Triple
beeps
Audio/
N.O.
2-24 Programming The Controller