Installation guide

Zone Monitor
This option selects a device to be connected to the RS-232 port, a
computer monitor for logging of all zone or group zone paging activity.
The default setting is off.
Computer Monitor
By selecting Zone Monitor, the PagePac Plus is enabled to monitor activity
Mode
on specific zone or group zone. This feature requires that a PC computer
be connected to the RS-232 port of the PagePac Plus Controller.
Whenever the input becomes active, ASCII characters will be sent out the
RS-232 port to the monitor. The ASCII characters will be intercepted by a
special software package in the computer that logs the time, date, input
zone, type of activity, zone that was paged, and duration of the activity.
All such input activity to the paging system can then be viewed (and
recorded) on the computer.
Programming Steps First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ]. The default setting for
this option is Computer Monitor.
NOTE: For Zone or group zone
1.
Dial [
6
] [
6
] to select this option.
level monitoring see the Zone
Monitor section.
Hear a DOUBLE beep.
2.
Dial the code to activate this option:
[
0 ] to select OFF
[
0
] to select ON.
Hear TRIPLE beeps.
To verify the status of this option, dial [
6 ] [ 7 ] and repeat step 2 above.
These actions are summarized in table 2-14.
Table 2-14. Computer Monitor Option
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Choose Option
Listen
For
Default
Computer
Monitor
To Select
To Verify
66
67
Double
Beep
Enter zone or
group number
0 - OFF
1 - ON
Triple
Beeps
OFF
Programming The Controller
2-21