Installation guide

Type of Zone: Input or Output
The choices here are INPUT #1, INPUT #2, and OUTPUT. Be sure the
manually selectable Zone Option switch on the rear of the PagePac Plus
NOTE: The INPUT #l option
Controller is set to match the type of zone selected (input or output).
must only be assigned to
Input #1 would be used for an emergency alert, say a connection to your
physical zones 1 through 8. alarm system. Input #2 would be a lower priority, say a doorbell input.
The factory default is OUTPUT (i.e., all zones are output type, by default).
Programming Steps
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ].
1.
2.
3.
Dial [
6
] [
2
] to select this option.
Hear a DOUBLE beep.
Enter the number of the zone or zone group to be optioned. Use
ALIAS numbers, if optioned. Otherwise, use Physical zone/group
numbers.
Hear a DOUBLE beep.
Enter [
0 ] to designate the zone as OUTPUT
Enter [
1 ] to designate it as INPUT #1
Enter [
2 ] to designate it as INPUT #2
Hear TRIPLE beeps.
To verify the zone type assignment, dial [
6 ] [ 3 ] and repeat steps 2 and 3
above.
These actions are summarized in table 2-13.
Table 2-13. Type of Zone
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Type of To Select
62
Double
Enter
Double
0 – Output
Triple Output
Zone
To Verify
63
Beep
zone/group
Beep
1 – Input 1
Beeps
number.
2 – Input 2
Programming The Controller
2-19