Installation guide

Programming Options and Instructions
CAUTION:
The Zone Option switches must be set before the PagePac Plus system is
powered up, and therefore before programming commences.
The 8 Zone Option switches on the rear of the PagePac Plus unit MUST
be set to match the zone option selected via programming. The slide
switch for each zone must be manually set to Contact Closure (to switch
on/off a device, such as a door security lock, remote amplifier, etc.), Input,
or Audio Output, depending on the mode selected for each zone.
The 16 Zone Option switches on the Zone Expansion Unit MUST also be
configured to match the zone modes you intend to program.
It is recommended that the paging zone decisions be made and
diagramed prior setting these switches. See Zone Configuration Tables
(1-3 and 1-4 in section 1, to be filled out) and programming instructions,
below.
Enter Programming Mode
To enter the programming mode:
1.
2.
3.
4.
5.
Access the PagePac Plus system via the telephone interface (dial the
paging access extension).
Dial the Connect password (if optioned). (See Connect Password,
below.)
Hear the PagePac Plus dial tone.
Dial [
* ] [ * ]. Hear confirmation tone and then dial tone again.
Dial the Programming password (if optioned). (See Programming
Password, below.)
Program the system options (go on to the next paragraphs). You
may exit the programming mode by dialing [
#
] .
System Configuration Options Overview
System Configuration Options are options that effect the entire system,
and are not specific or unique to any one zone or zone group. See the
Programming Quick Reference Chart at the end of this section for a listing
of these. The paragraphs below provide instructions for programming
these system options (from a telephone keypad), if you wish to change
them.
Programming The Controller
2-5