Installation guide

Table 1-1. Zone Map Example
Description of Zone
Physical
Zone
Number
Physical
Zone
Code
ALIAS*
Zone
Number
Input (1 or 2) or
Output
Warehouse Area Paging
Zone 2
02
212
0
Shipping/Receiving Area
Zone 3
03
213
0
Paging
Doorbell: Security Door,
S/R Dock
Zone 4
04
223
I-2
Speaker-phone: Security
Door, S/R Dock
Zone 5
05
221
0
Door Lock: Security Door,
S/R Dock
Zone 6 06
222
0
Garage Area Paging
Zone 7
07
214
0
Security Alarm System input
Zone 8
08
231
I-1
All Call: Group all paging
(for audio): zones 1,2,3, & 7
Group 1 80
241
0
Group warehouse / shipping
Group 2
81
area paging zones: 2 & 3
242
0
* Optional