Specifications
Specifications
Table 4 describes the specifications of the AmpliCenter D20, D100, and
D300 models.
Table 4. AmpliCenter Specifications
Features
Telephone Paging Access: The AmpliCenter accepts inputs from telephone system (PBX) ground■
start or loop start trunk ports, dry loop 600 ohm page ports, dry loop (hi Z), or amplified microphones.
Music interface: The AmpliCenter is the unit to which the background music source (CD, radio, tape
■
player) is connected, for distribution to the paging system.
Volume control: The AmpliCenter has music ducking (mute) level, music volume level, and bass
■
control adjustment pots on the rear panel. Overall output level can be controlled by dialing a DTMF
code.
Remote amplifier connection: The AmpliCenter provides 0 dBm audio output for connection to a
■
remote amplifier, which receives a contact closure control signal from the AmpliCenter.
■
D20: up to 20 Watts total speaker load, for a 70V constant voltage distribution system.
Rated Power
D100: up to 100 Watts, for a 70V constant voltage distribution system.■
■
D300: up to 300 Watts, for a 70V constant voltage distribution system.
Dimensions
■
D20 and D100: 3-1/2" (8.9 cm) high x 19" (48.25 cm) wide x 5" (12.7 cm) deep.
■ D300: 3-1/2" (8.9 cm) high x 19" (48.25 cm) wide x 7.25" (18.4 cm) deep
Weight
D20: 5 lbs (11kg); D100: 6 lbs (13 kg); D300: q 7 lbs (14 kg)■
Load Impedance
■
Minimum, D20: 250 ohms, D100: 50 ohms, D300: 16.7 ohms
Frequency
60Hz to 16Khz
■
Response
Total Harmonic
■ Less than 1%, at rated power, 60 Hz to 16 kHz
Distortion
Hum and Noise
Less than 80 dB below rated output, 20 Hz to 20 kHz bandwidth, unweighted■
Telephone
Automatic Level Control: 15:1 compression ration above -15dBm input; Gain Below Limiting Knee:■
Paging Access
56dB; ALC Attack Time: Less than 3 msec.
Music Input
Sensitivity: 180 mV for rated output, single channel input. 90 mV with both inputs driven.■
■
Impedance: 20 kohms, un-balanced, each input (left & right)
Overload
Current limiting, thermal shutdown, short circuit, reactive load, and internal DC fault protection.■
Protection
Approvals
■
U.L. 813, C.S.A 950, NRTL/C
RJ-11 Jack
Talk battery 24 volts, loop start or ground start, negative voltage ring lead
■
Specifications
Impedence: 600
Ω and 100K
■ Ω
Temperature
0 to 40 deg. C. (32°F to 104°F) operational; to +50 deg. C. (122°F) with forced air
■
Range:
■
–20 to +70 deg. C. (28°F to 158°F) storage and shipment
Environmental
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals.
■
Requirements
Humidty: 5% to 95% (non-condensing) storage/shipment and operation. Altitude: sea level to 10,000
ft. (1048 to 648 millibars) operational; 40,000 ft max. shipment.
Electrical, Power,
110-125 VAC, 57-63 HZ; or 220-240 VAC 47-53 Hz (automatic selection)
■
and Grounding
Requirements:
■
Outlet must be a 3-prong outlet, separate ground, not controlled by an on/off switch
D20: 1 amp max., D100: 2.5 amp/1.25 amp max., D300: 8 amp/ 4 amp max.
■
A. Use the power cord supplied with the unit, or an equivalent cord that meets applicable safety
■
codes. Do not cut or remove the third wire ground prong.
B. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
■
grounding type, and the grounding conductors serving these receptacles are to be connected to
earth ground at the service equipment.
14