Specifications

Specifications
Table 4 describes the specifications of the AmpliCenter D20, D100, and
D300 models.
Table 4. AmpliCenter Specifications
Features
Telephone Paging Access: The AmpliCenter accepts inputs from telephone system (PBX) ground
start or loop start trunk ports, dry loop 600 ohm page ports, dry loop (hi Z), or amplified microphones.
Music interface: The AmpliCenter is the unit to which the background music source (CD, radio, tape
player) is connected, for distribution to the paging system.
Volume control: The AmpliCenter has music ducking (mute) level, music volume level, and bass
control adjustment pots on the rear panel. Overall output level can be controlled by dialing a DTMF
code.
Remote amplifier connection: The AmpliCenter provides 0 dBm audio output for connection to a
remote amplifier, which receives a contact closure control signal from the AmpliCenter.
D20: up to 20 Watts total speaker load, for a 70V constant voltage distribution system.
Rated Power
D100: up to 100 Watts, for a 70V constant voltage distribution system.
D300: up to 300 Watts, for a 70V constant voltage distribution system.
Dimensions
D20 and D100: 3-1/2" (8.9 cm) high x 19" (48.25 cm) wide x 5" (12.7 cm) deep.
D300: 3-1/2" (8.9 cm) high x 19" (48.25 cm) wide x 7.25" (18.4 cm) deep
Weight
D20: 5 lbs (11kg); D100: 6 lbs (13 kg); D300: q 7 lbs (14 kg)
Load Impedance
Minimum, D20: 250 ohms, D100: 50 ohms, D300: 16.7 ohms
Frequency
60Hz to 16Khz
Response
Total Harmonic
Less than 1%, at rated power, 60 Hz to 16 kHz
Distortion
Hum and Noise
Less than 80 dB below rated output, 20 Hz to 20 kHz bandwidth, unweighted
Telephone
Automatic Level Control: 15:1 compression ration above -15dBm input; Gain Below Limiting Knee:
Paging Access
56dB; ALC Attack Time: Less than 3 msec.
Music Input
Sensitivity: 180 mV for rated output, single channel input. 90 mV with both inputs driven.
Impedance: 20 kohms, un-balanced, each input (left & right)
Overload
Current limiting, thermal shutdown, short circuit, reactive load, and internal DC fault protection.
Protection
Approvals
U.L. 813, C.S.A 950, NRTL/C
RJ-11 Jack
Talk battery 24 volts, loop start or ground start, negative voltage ring lead
Specifications
Impedence: 600
and 100K
Temperature
0 to 40 deg. C. (32°F to 104°F) operational; to +50 deg. C. (122°F) with forced air
Range:
–20 to +70 deg. C. (28°F to 158°F) storage and shipment
Environmental
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals.
Requirements
Humidty: 5% to 95% (non-condensing) storage/shipment and operation. Altitude: sea level to 10,000
ft. (1048 to 648 millibars) operational; 40,000 ft max. shipment.
Electrical, Power,
110-125 VAC, 57-63 HZ; or 220-240 VAC 47-53 Hz (automatic selection)
and Grounding
Requirements:
Outlet must be a 3-prong outlet, separate ground, not controlled by an on/off switch
D20: 1 amp max., D100: 2.5 amp/1.25 amp max., D300: 8 amp/ 4 amp max.
A. Use the power cord supplied with the unit, or an equivalent cord that meets applicable safety
codes. Do not cut or remove the third wire ground prong.
B. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be connected to
earth ground at the service equipment.
14