User guide
DEFINITY Performance Management User Guide, Release 2.0, 585-229-808
9 Set Alerting Parameters
Set Global Alerting Parameters
Issue 1
November 1998
Page 193
• If
no
, leave the box unchecked. The system will not record any call
processing occupancy exceptions in the event log.
The G3r occupancy threshold field reflects the maximum percent of CPU
occupancy being used by the call processing software for DEFINITY G3r
switches before an event is generated. Enter the threshold percent in this
field by typing the percent or by clicking the up or down arrows to obtain
the desired percent.
The Non-Gr3 occupancy threshold field sets the default call processing
occupancy threshold for switches other than the DEFINITY Gr3. Fill in this
field as described in the G3r field.
6 In the Trunk Groups box, do you want the system to record trunk group grade
of service exceptions in the event log?
• If
yes
, put a check mark in the box next to “Log event when exception
occurs”. Set the alert level for the event by clicking on the arrow in the
Alert level pull-down list and selecting one of the options.
• If
no
, leave the box unchecked. The system will not record any trunk
group grade of service exceptions in the event log.
In the Model field, select the model to use in calculating trunk group grade
of service. Choose the model whose assumptions most closely match
your situation.
The Erlang B model assumes that calls that are blocked from accessing
the trunk group are cleared from the system.