Instruction manual
Specifications
A
Capacities
System
206E/206EC Module
Extension Jack
■
24 outside lines via line jacks on
■
2 outside lines
■
Maximum 2 devices per extension
four 206 plus four 400 modules
■
6 extensions
jack, total REN on jack not to
■
48 extensions via extension jacks
exceed 2.0* (System phone REN
on eight 206 modules
400E/400EC Module
is 0.0 (zero))
■
1 loudspeaker paging system
4 outside lines
■
No more than one system phone
via PAGE jack on processor
module
per jack
■
1 audio source via MUSIC ON
For programming, a system display
HOLD jack on processor module
phone must be connected to
(RCA phono plug required)
extension 10 or 11.
■
1 call reporting device via SMDR
jack on processor module (355A/F
adapter required)
■
2 doorphones, using 2 ext. jacks
Dimensions
■
Primary Proc. Mod.
11"(D) x 17"(H) x 1.5"(W) or 27.9 x 43.2 x 3.8 cm
4.0 lbs or 1.8 kgs
and Weights
■
Exp. Proc. Mod.
11"(D) x 17"(H) x 1.5"(W) or 27.9 x 43.2 x 3.8 cm
4.0 lbs or 1.8 kgs
(approx.)
■
206E/206EC module 11"(D) x 17"(H) x 1.5"(W) or 27.9 x 43.2 x 3.8 cm
4.5 lbs or 2.0 kgs
■
400E/400EC module 11"(D) x 17"(H) x 1.5"(W) or 27.9 x 43.2 x 3.8 cm
4.0 lbs or 1.8 kgs
■
Backplane & cover
12"(D) x 19"(H) x 11"(W) or 30.5 x 48.3 x 27.9 cm
5.5 lbs or 2.5 kgs
■
MLS-34D phone
9.7"(D) x 5.3"(H) x 10"(W) or 24.6 x 13.5 x 25.4 cm
3.1 lbs or 1.4 kgs
■
MLS-18D phone
9.5"(D) x 5"(H) x 6.75"(W) or 24.1 x 12.7 x 17.1 cm 2.8 lbs or 1.3 kgs
■
MLS-12D phone
9.5"(D) x 5"(H) x 6.75"(W) or 24.1 x 12.7 x 17.1 cm
2.8 lbs or 1.3 kgs
■
MLS-12 phone
9.5"(D) x 5"(H) x 6.75"(W) or 24.1 x 12.7 x 17.1 cm
2.7 lbs or 1.2 kgs
■
MLS-6 phone
9.5"(D) x 5"(H) x 6.75"(W) or 24.1 x 12.7 x 17.1 cm
2.7 lbs or 1.2 kgs
■
MLC-6 phone 9.4"(D) x 3.4"(H) x 7"(W) or 23.9 x 8.6 x 17.8 cm 2.8 lbs or 1.3 kgs
■
MLS-CA24 Autodialer
9.7"(D) x 5.3"(H) x 3.4"(W) or 24.6 x 13.5 x 8.6 cm
1.3 lbs or 0.6 kgs
Switch Fabric
■
Full digital, nonblocking
Electrical
■
10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption
Specifications
■
65 Watts (225 BTU/hour) per 206 module during normal operation
■
100 Watts (350 BTU/hour) per 206 module during maximum power consumption
■
8 Amps maximum current at full system capacity (two carriers with processor module and four 206
modules each)
On a PARTNER II 220V System: 2.2 Amps maximum current
■
4-day memory backup (96 hours)
* The two devices combined on an extension jack can be a system phone with a standard device, or two standard devices; DO NOT
connect two system phones to the same extension jack. If a device lists two RENs, use the higher number when adding RENs.
Specifications
A-1