Instruction manual

Recall Timer Duration (#107)
Description
This System Programming procedure lets you change the length of the timed
signal, or switchhook flash, generated by the system Recall feature (as well as
by the Recall function used in Auto Dial or Speed Dial numbers). Recall sends
this timed signal over the phone line to the local telephone company or PBX to
which the system is connected. Typically you use the Recall feature to access
PBX or Centrex features such as Call Waiting.
Considerations
You should only change the factory setting of the Recall Timer under two
conditions:
If using the system Recall feature has no effect, lengthen the time.
If your system is connected to a PBX or Centrex system and Recall
drops calls, then you should shorten the time.
Valid Entries
01 through 80 (25 to 2000 msec. in 25 msec. increments)
18 (450 msec.)
Programming
To change the duration of the Recall Timer signal:
1.
Press [
Feature
] [
0
] [
0
] [
System Program
] [
System Program
][
#
] [
1
] [
0
] [
7
]. The
display reads:
Recall Timer
18 450-msec
2.
Enter a different recall timer setting by pressing [
Next Data
] or [
Prev Data
]. For
example, to increase the Recall timer to 750 msec., press [
Next Data
] until
the display reads:
Recall Timer
30 750-msec
Alternatively, you can enter the setting number directly. For example, to
set the Recall timer to 750 msec., press [
3
] [
0
].
3.
Select another procedure or exit programming mode.
4.
If you are using Recall to access PBX features, test the new Recall Timer
Duration:
If a call is disconnected, shorten the time.
If the Recall signal has no effect, lengthen the time.
Recall Timer Duration (#107)
5-109