Instruction manual
Installing the Carriers
2-37
Installing the Control Unit
Installing the Modules 2
CAUTION:
When installing the modules, use a properly grounded wrist strap to 
prevent damage from electrostatic discharge (ESD), and avoid touching 
leads, connectors, pins, and other components. The wrist strap can be 
clipped to the ground-screw or plugged into the hole next to the ground-
screw.
WARNING:
All unused slots must be covered with a blank panel. Remove back panels 
only from slots where modules will be installed.
Guidelines 2
Follow these guidelines when you install modules, as indicated on the Control 
Unit Diagram of Form 1, System Planning:
■ For a MERLIN MAGIX Release 1.0 system, do not leave empty slots 
between modules. The system ignores modules installed beyond any 
empty slot.
■ For a MERLIN MAGIX Release 1.5 system, you may leave empty slots 
between modules, but you must program these empty slots to be Bridge 
modules. (See “Upgrading to the MERLIN MAGIX System” on page 7-9.)
■ If a phantom module (a programmed empty slot) is indicated on the Control 
Unit Diagram, make sure the slot remains empty and do not install any 
modules to the right of it. The system ignores any modules installed to the 
right of a programmed empty slot.
■ Remove a blank panel from a slot by prying up the latch at the bottom of 
the panel with a flat bladed screwdriver.
■ Make sure you install each module in its assigned slot. If you install a 
module in the wrong slot, the system will not function properly.