Instruction manual
AC Power and Grounding
2-7
Installing the Control Unit
■ All AC outlets must connect to the same load center and the ground wire 
must connect to the single-point ground bar on the first AC outlet (see 
Figure 2-1).
■ One outlet must have an attached ground bar connected by a #6 AWG 
copper wire to an approved ground (see “Approved Grounds” later in this 
chapter, for a description of approved grounds). This ground bar is the 
system’s single-point ground (see Figure 2-1). 
■ To prevent someone from accidentally shutting off the power, do not 
connect the control unit to a switch-controlled outlet.
■ The AC outlet should be within 5 feet (152 cm) of the control unit.
■ Each carrier requires one AC outlet receptacle.
■ Auxiliary equipment requires additional AC outlets.
■ If a printer or PC is installed on the system, it must be plugged into the 
same AC branch as the power supply of the basic carrier.
■ If the printer or PC is 50 feet (15 m) or more from the control unit, or is 
plugged into a different AC circuit, Asynchronous Data Units (ADUs) must 
be installed as well. Chapter 5, “Installing the PC, CAT, or Printer” of the 
Installation manual includes complete installation instructions.
■ The AC power requirements indicated in “AC Outlet Tests”, must be met.